MJ-560B4 Anesthesia Machine

Part parameters

Packaging Details:
Delivery Time:
Description: MJ-560B4 Anesthesia Machine, With its ergonomic design, integrates a concise and smooth structure and high mobility. The microcomputer-controlled Ventilator adopts exported sensors and other components.

Detailed introduction:

MJ-560B4  Anesthesia Machine,  With its ergonomic design,  integrates a concise and smooth  structure and high mobility. The microcomputer-controlled Ventilator adopts exported sensors and other components. Its scientific and proper design as well as rigorous production process are what demonstrate the innerquality of Aokai products: mechanical ventilation is made secure and visible by the folded respiratory bellows. and the security of air supply is guaranteed by pneumatic transmission and measurement system. With multiple modern technologies applied, the Anesthesia Machine is both outstanding in performance and versatile in functions, supply. The machine brings together a number of technologies, is a machine of fine performance and complete function.

 

1. The Ventilator adopts microcomputer control with high-definition 5.7 "  LCD display, integrating the functions of respiratory control and displaying the monitoring parameters.
2. The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure,temperature and flow rate, And it is available to choose two kinds of gas from Halothane, Enflurane,
Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation.
3. High-definition four-tube flowmeter, designed with stoppers for oxygen and nitrous oxide to control the output oxygen concentration
4 . Reliable pneumatic transmission system
5 . Economic and proper configuration of technologies, optional as required by the Customer
6 . Modularized design and upgrading. Upgrading is available as required by the customer.

 

 

 

  
  Anesthesia Machine  
* Main body High-strength engineering plastic rack, light, beautiful and corrosion resistant
* Scope of application aduit, child
* Gas source O2: 0.27~0.55MPa    N2O : 0.27~0.55MPa
* Flow meter O2:0.1~1.0L/min      1.1~10L/min
N2O : 0.1~1.0L/min    1.1~10L/min
* O2, N2O linkage and N2O Stopper
  When using nitrous oxide, oxygen concentration>25%; When the oxygen pressure<0.2KPa, the flow of nitrous oxide would be cut off.
* Flow rate of rapid oxygen supply 25~75L/min
* Low oxygen pressure alam There will be sound alarm when the oxygen pressure <0.2MPa
* Vaporizer
  it has the function of automatic compensation based on pressure, temperature and flow rate, The regulation range of evaporator concentration is 0-5 vol%. Among Halothane, Enflurane, lsoflurane and Sevoflurane, one can be chosen for application as required by the customer.And vaporizers that are imported with original packaging are also available.
* Low oxygen pressure alarm There will be sound alarm when the oxygen pressure <0.2 MPa
* Respiratory circuit work mode : all close, semi-close, semi-open APL: 0.5~7KPa
* Respiratory Bellows bellows for adults, bellows for children tidal volume range: 0~1500ml
 

 

 

  Ventilator  
* Display mode High-definition 5.7 " LCD screen display
* Ventilation mode  
  IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH,
* Ventilation parameters  
  Tidal volume 50~1500ml
  Rate 2~99bpm
  SIMV rate 2~20bpm
  I : E 2:1~1:8
Inspiratory trigger pressure -1.0~2.0KPa
PEEP 0-2.0KPa
  Pressure range 1.0~6.0kpa
SIGH 1.5 times the inspiratory time
   
* Parameters for ventilation monitoring
  tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate,I/E, peak pressure of airway, pressure - time waveform, flow rate - time waveform ,PEEP ,inspiratory trigger pressure,
* Monitoring of oxygen concentration 21%~100%
* Security Alert System  
  Oxygen Concentration alarm upper limit setting range 50%-100%
low limit setting range 15%-50%
Airway pressure alarm upper limit setting range 1.0-6.0kpa
low limit setting range 0.4-2.0kpa
  Per - minute ventilation volume alarm upper limit setting range 3.0-30L/min
low limit setting range 1.0-10L/min
  Sustained high - pressure alarm it will give alarm when stress have
consistently been higher than 2.5 kpa
  Suffocation alarmPower alarm it will give sound and light alarm if there is
no tidal volume input for 15 seconds
* Power AC 220v±10% 50Hz ±1HZ
( UPS, Storage battery )
* Mechanical Arms
End-tidal CO2 monitoring
Items within brackets are optional

 